Mathematical Modeling and Forecasting of the Annual Efficiency of Flat-Plate Solar Collectors in the Fergana Valley

Authors

Abstract

A south-facing flat-plate solar collector in Fergana (40.39° N, 71.79° E) is predicted to deliver about 909 kWh/m² of useful heat per year at its optimal tilt of 30°, a mean annual efficiency of 51%. The forecast is built only from ground-station climate normals: monthly sunshine duration and air temperature. Global horizontal irradiation was estimated with the Ångström–Prescott equation and split into beam and diffuse parts with the Erbs monthly correlation. It was transposed to the tilted plane with the isotropic Liu–Jordan model and distributed over the day with the Collares-Pereira–Rabl ratios. Collector output was computed in steps of about 2 minutes for a mean day of each month with the Hottel–Whillier–Bliss equation and an incidence angle modifier. The estimated global horizontal irradiation is 1,614 kWh/m² per year. Monthly efficiency ranges from 21% in December to 63% in July and August, so the collector is a summer-dominated heat source. Raising the inlet temperature from 30 °C to 60 °C lowers annual efficiency from 60% to 36%. Each 5% loss of optical efficiency from dust lowers annual yield by about 6.6%. The method suits sites in the Fergana Valley that have sunshine records but no pyranometer.
Keywords: flat-plate solar collector; thermal efficiency; Ångström–Prescott equation; sunshine duration; tilt angle; dust soiling; Fergana Valley; Uzbekistan

References

1. Madaminov J., Ergashev I., Rustamova M., Tohirov I., Kodirov M., Valixonov D., Mirzayev M. Efficiency of using a solar air heating collector in a continental climate. E3S Web of Conferences, 2024, 592, 01014. https://doi.org/10.1051/e3sconf/202459201014

2. Climate normals for Fergana: sunshine hours 1961–1990 (NOAA); temperature 1981–2010 (Uzhydromet). Compiled in: Fergana — climate table, Wikipedia.

3. Tiangco C. Update on Solar Development in Uzbekistan. Asian Development Bank, 8th Meeting of the Asia Solar Energy Forum, Manila, 2015.

4. Egamberdiev H.T., Abdikulov F.I. Long-term change of total solar radiation at the Fergana actinometric station (1961–2015). https://api.ziyonet.uz/uploads/books/1304363/5b30e480d042c.pdf

5. Avezova N., Frid S., Lisitskaya N., Rakhimov E. Resource indicators of solar photovoltaic plants in the Republic of Uzbekistan. Part 2. Verifying satellite actinometric and reanalysis data for conditions in Uzbekistan. Applied Solar Energy, 2019, 55(5). https://doi.org/10.3103/S0003701X19050037

6. Ångström A. Solar and terrestrial radiation. Quarterly Journal of the Royal Meteorological Society, 1924, 50, 121–126.

7. Prescott J.A. Evaporation from a water surface in relation to solar radiation. Transactions of the Royal Society of South Australia, 1940, 64, 114–118.

8. Allen R.G., Pereira L.S., Raes D., Smith M. Crop Evapotranspiration: Guidelines for Computing Crop Water Requirements. FAO Irrigation and Drainage Paper 56. Rome: FAO, 1998.

9. Erbs D.G., Klein S.A., Duffie J.A. Estimation of the diffuse radiation fraction for hourly, daily and monthly-average global radiation. Solar Energy, 1982, 28(4), 293–302.

10. Liu B.Y.H., Jordan R.C. The interrelationship and characteristic distribution of direct, diffuse and total solar radiation. Solar Energy, 1960, 4(3), 1–19.

11. Collares-Pereira M., Rabl A. The average distribution of solar radiation — correlations between diffuse and hemispherical and between daily and hourly insolation values. Solar Energy, 1979, 22(2), 155–164.

12. Duffie J.A., Beckman W.A. Solar Engineering of Thermal Processes, 4th ed. Hoboken: Wiley, 2013.

13. Hottel H.C., Whillier A. Evaluation of flat-plate solar collector performance. Transactions of the Conference on the Use of Solar Energy, Tucson, 1955 (publ. 1958), vol. 2, part I, 74–104.

14. Bliss R.W. The derivations of several “plate-efficiency factors” useful in the design of flat-plate solar heat collectors. Solar Energy, 1959, 3(4), 55–64.

15. Souka A.F., Safwat H.H. Determination of the optimum orientations for the double-exposure, flat-plate collector and its reflectors. Solar Energy, 1966, 10(4), 170–174.

16. Klein S.A. Calculation of monthly average insolation on tilted surfaces. Solar Energy, 1977, 19(4), 325–329.

17. Sarver T., Al-Qaraghuli A., Kazmerski L.L. A comprehensive review of the impact of dust on the use of solar energy. Renewable and Sustainable Energy Reviews, 2013, 22, 698–733.

18. Fergana monthly temperature normals, 1991–2020. Climates to Travel. https://www.climatestotravel.com/climate/uzbekistan/fergana

Downloads

Published

04.11.2026

How to Cite

Yusupov, Y. (2026). Mathematical Modeling and Forecasting of the Annual Efficiency of Flat-Plate Solar Collectors in the Fergana Valley. Bulletin of Contemporary Researches, 2(4), 86-90. https://bulconre.com/index.php/mult/article/view/47